MAK 10 Technical Information

MAK 10-1

MAK 10-2

MAK 10-4

MAK10-1-PS1

MAK10-2-PS2

Technical Data
Number of gas paths
1
2
4
1
2
Pre-separator (PS)
-
-
-
1
2
Operation Data
Gas flow per gas path dew-point at inlet 65°C 125NI/h 2.0lpm 125NI/h 2.0lpm 100NI/h 1.7lpm 150NI/h 2.5lpm 150NI/h 2.5lpm
Gas flow per gas path dew-point at inlet 55°C 175NI/h 2.9lpm 175NI/h 2.9lpm 140NI/h 2.3lpm 200NI/h 3.3lpm 200NI/h 3.3lpm
Gas-temp at inlet max
140 °C
Ambient temperature
5 - 45 °C
Operating Pressure (abs.)
0.5 - 2.0 bar
Gas dew-point at outlet
3.0 °C +/- 0.3 °C
Pressure drop per gas path
5 mbar (V = 125 N I/H)
Dead space per gas path
26 ml
Ready for start up
< 5 min.
< 10 min.
< 15 min
< 5 min.
< 10 min.
Cooling capacity temp = 45 °C
220 W
220 W
300 W
220 W
220 W
Material of gas path
Cooling transfer tube
Aluminum
Cooling surface
PTFE-Coating
Housing/Sealings
PVDF/Viton
Design data
Width
310 mm
310 mm
449 mm
310 mm
449 mm
Height
266 mm
266 mm
266 mm
266 mm
266 mm
Depth
321 mm
321 mm
321 mm
321 mm
321 mm
Weight
16 kg
18 kg
23 kg
17 kg
20 kg
Housing
Wall-mount- optional 19"/Rail 7032
Gas connection
PVDF DN 4/6
Condensate connection
PVDF DN 4/6
Electrical Data
Mains connection
Plug
3-pole alarm contact
25 V AC, 2A
Alarm set points
< +2 °C / > +10 °C
Housing protection class
IP 20 EN 60529 / EN 61010
Power supply
230 V 50/60 Hz (+15%/-15%)
Power consumption max.
170/185 W
170/185 W
170/185 W
170/185 W
170/185 W
Power supply
115 V 50/60 Hz (+10%/-10%)
Power consumption max.
170/195 W
170/195 W
170/195 W
170/195 W
170/195 W