MAK 10-1
|
MAK 10-2
|
MAK 10-4
|
MAK10-1-PS1
|
MAK10-2-PS2
|
Technical Data |
Number of gas paths |
1 |
2 |
4 |
1 |
2 |
Pre-separator (PS) |
- |
- |
- |
1 |
2 |
Operation Data |
Gas flow per gas path dew-point at inlet 65°C |
125NI/h 2.0lpm |
125NI/h 2.0lpm |
100NI/h 1.7lpm |
150NI/h 2.5lpm |
150NI/h 2.5lpm |
Gas flow per gas path dew-point at inlet 55°C |
175NI/h 2.9lpm |
175NI/h 2.9lpm |
140NI/h 2.3lpm |
200NI/h 3.3lpm |
200NI/h 3.3lpm |
Gas-temp at inlet max |
140 °C |
Ambient temperature |
5 - 45 °C |
Operating Pressure (abs.) |
0.5 - 2.0 bar |
Gas dew-point at outlet |
3.0 °C +/- 0.3 °C |
Pressure drop per gas path |
5 mbar (V = 125 N I/H) |
Dead space per gas path |
26 ml |
Ready for start up |
< 5 min. |
< 10 min. |
< 15 min |
< 5 min. |
< 10 min. |
Cooling capacity temp = 45 °C |
220 W |
220 W |
300 W |
220 W |
220 W |
Material of gas path |
Cooling transfer tube |
Aluminum
|
Cooling surface |
PTFE-Coating
|
Housing/Sealings |
PVDF/Viton
|
Design data |
Width |
310 mm |
310 mm |
449 mm |
310 mm |
449 mm |
Height |
266 mm |
266 mm |
266 mm |
266 mm |
266 mm |
Depth |
321 mm |
321 mm |
321 mm |
321 mm |
321 mm |
Weight |
16 kg |
18 kg |
23 kg |
17 kg |
20 kg |
Housing |
Wall-mount- optional 19"/Rail 7032 |
Gas connection |
PVDF DN 4/6 |
Condensate connection |
PVDF DN 4/6 |
Electrical Data |
Mains connection |
Plug |
3-pole alarm contact |
25 V AC, 2A |
Alarm set points |
< +2 °C / > +10 °C |
Housing protection class |
IP 20 EN 60529 / EN 61010 |
Power supply |
230 V 50/60 Hz (+15%/-15%) |
Power consumption max. |
170/185 W |
170/185 W |
170/185 W |
170/185 W |
170/185 W |
Power supply |
115 V 50/60 Hz (+10%/-10%) |
Power consumption max. |
170/195 W |
170/195 W |
170/195 W |
170/195 W |
170/195 W |