ECOM J2KN Portable Gas Analyzer

ECOM J2KN Standard Features:
  • 3.5+ lpm pump
  • On-board flow meter
  • Smoke test capability
  • On-board impact printer
  • Thermo-electric gas cooler
  • Automatic CO over-range protection
  • Internal pump with fresh air bypass/purge
  • Stack temperature and draft measurement
  • Moisture trap with automatic moisture dump
  • Operation manual and protective storage case
  • Ambient, flue gas, sensor temperature measurement
  • Wireless handheld remote control with backlit LCD display.
  • Sample line (15') with probe (1')- other lengths available
  • Advanced DAS 2.0 software compatible plus wireless data transmission to your PC.
  • Spare consumables: filters, printer paper, smoke test disks, etc..
  • Analyzer with up to 5 EC sensors for measurement of: 02, CO, NO, NO2, SO2, combustibles (CH4).
  • CO2, efficiency, losses, excess air, and oxygen correction calculations.
ECOM J2KN Analyzer with sample line
The ECOM J2KN with wireless remote control is a portable emission analyzer offering world-class performance in a rugged, user-friendly package.
Part Number
ECOM J2KN Handheld Remote
ECOM J2KN Analyzer
ECOM J2KN in use
The ECOM J2KN portable gas analyzer comes standard with 5 gas sensors to measure O2, CO, NO, NO2 and SO2, along with gas and ambient temperatures, stack draft & pressure, plus calculations of CO2, efficiency, excess air, and oxygen correction to 20%. The ECOM J2KN’s portable handheld remote allows complete operation of the analyzer showing all values at a glance, zoom display capability, and plug-in memory up to 256 MB. The ECOM J2KN is an ideal emission analyzer where combustion controls are located away from the flue test port.
Measurement (Key)
Range
Accuracy
Resolution
Life
Sensor Type
Oxygen (O)
0-21%
± 2% Measured 0.1% vol. 2 Years Electrochemical
Carbon Monoxide (C)
0-4,000 PPM
± 2% Measured 1 ppm 3 Years Electrochemical
Carbon Monoxide (V)
0-40,000 PPM
± 2% Measured 1 ppm 3 Years Electrochemical
Nitric Oxide (N)
0-4,000 PPM
± 2% Measured 1 ppm 3 Years Electrochemical
Nitric Oxide (.N)
0-400 PPM
± 2% Measured 0.1 ppm 3 Years Electrochemical
Nitrogen Dioxide (X)
0-500 PPM
± 2% Measured 1 ppm 3 Years Electrochemical
Nitrogen Dioxide (.X)
0-50 PPM
± 2% Measured 0.1 ppm 3 Years Electrochemical
Sulfur Dioxide (S)
0-5000
± 2% Measured 1 ppm 3 Years Electrochemical
Combustibles (H)
0-6.00%
± 2% Measured 0.01% 5 Years Peellister
Gas Temperature
32-1800°F
± 2% Measured 1°F 10 Years NiCrNi
Ambient Temperature
0-250°F
± 2% Measured 1°F 10 Years SemiConductor
Draft/Pressure
± 40" H2O
± 2% Measured 0.1 % H20 10 Years DMS
O2 Correction
0-20% Oxygen
       
Smoke Scale
0-9
       
Carbon Dioxide (CO2)
0-CO2 max of fuel
Calculated      
Efficiency
0.99.9%
Calculated      
Excess Air (Lambda)
1- infinity
Calculated      
*Accuracy: When calibrated prior to use per ECOM America, Ltd. specifications.
Physical:
  • Instrument: 16 " x 10" x 12 "
  • Probe: 13" Length x 3/8" O.D. Inconel with pistol grip handle*
  • Sample Line: 15' high temp flex hose with thermocouple wire*
  • Weight: 28 lbs
Electrical:
  • AC: 110/220V 50/60Hz (User selectable)
  • Batteries: 6-8 hour battery life, 6V lead-acid
  • Pump: Flow rate of 3.5+ lpm
  • Display: Backlit, adjustable contrast/zoom, (Displays all parameters simultaneously)
Operating Temperature:
  • Core temperature of the instrument is monitored continuously
  • Internal temperature compensation software assures accurate sensor response over the range of 20°F to 104°F