ECOM J2KN Portable Gas Analyzer
|
|
ECOM J2KN Standard Features: |
- 3.5+ lpm pump
- On-board flow meter
- Smoke test capability
- On-board impact printer
- Thermo-electric gas cooler
- Automatic CO over-range protection
- Internal pump with fresh air bypass/purge
- Stack temperature and draft measurement
- Moisture trap with automatic moisture dump
- Operation manual and protective storage case
- Ambient, flue gas, sensor temperature measurement
- Wireless handheld remote control with backlit LCD display.
- Sample line (15') with probe (1')- other lengths available
- Advanced DAS 2.0 software compatible plus wireless data transmission to your PC.
- Spare consumables: filters, printer paper, smoke test disks, etc..
- Analyzer with up to 5 EC sensors for measurement of: 02, CO, NO, NO2, SO2, combustibles (CH4).
- CO2, efficiency, losses, excess air, and oxygen correction calculations.
|
|
|
|
The ECOM J2KN with wireless remote control is a portable emission analyzer offering world-class performance in a rugged, user-friendly package. |
|
|
|
|
The ECOM J2KN portable gas analyzer comes standard with 5 gas sensors to measure O2, CO, NO, NO2 and SO2, along with gas and ambient temperatures, stack draft & pressure, plus calculations of CO2, efficiency, excess air, and oxygen correction to 20%. The ECOM J2KN’s portable handheld remote allows complete operation of the analyzer showing all values at a glance, zoom display capability, and plug-in memory up to 256 MB. The ECOM J2KN is an ideal emission analyzer where combustion controls are located away from the flue test port. |
|
|
Accuracy |
Resolution |
Life |
Sensor Type |
Oxygen (O) |
0-21% |
± 2% Measured |
0.1% vol. |
2 Years |
Electrochemical |
Carbon Monoxide (C) |
0-4,000 PPM |
± 2% Measured |
1 ppm |
3 Years |
Electrochemical |
Carbon Monoxide (V) |
0-40,000 PPM |
± 2% Measured |
1 ppm |
3 Years |
Electrochemical |
Nitric Oxide (N) |
0-4,000 PPM |
± 2% Measured |
1 ppm |
3 Years |
Electrochemical |
Nitric Oxide (.N) |
0-400 PPM |
± 2% Measured |
0.1 ppm |
3 Years |
Electrochemical |
Nitrogen Dioxide (X) |
0-500 PPM |
± 2% Measured |
1 ppm |
3 Years |
Electrochemical |
Nitrogen Dioxide (.X) |
0-50 PPM |
± 2% Measured |
0.1 ppm |
3 Years |
Electrochemical |
Sulfur Dioxide (S) |
0-5000 |
± 2% Measured |
1 ppm |
3 Years |
Electrochemical |
Combustibles (H) |
0-6.00% |
± 2% Measured |
0.01% |
5 Years |
Peellister |
Gas Temperature |
32-1800°F |
± 2% Measured |
1°F |
10 Years |
NiCrNi |
Ambient Temperature |
0-250°F |
± 2% Measured |
1°F |
10 Years |
SemiConductor |
Draft/Pressure |
± 40" H2O |
± 2% Measured |
0.1 % H20 |
10 Years |
DMS |
O2 Correction |
0-20% Oxygen |
|
|
|
|
Smoke Scale |
0-9 |
|
|
|
|
Carbon Dioxide (CO2) |
0-CO2 max of fuel |
Calculated |
|
|
|
Efficiency |
0.99.9% |
Calculated |
|
|
|
Excess Air (Lambda) |
1- infinity |
Calculated |
|
|
|
*Accuracy: When calibrated prior to use per ECOM America, Ltd. specifications. |
|
Physical: |
- Instrument: 16 " x 10" x 12 "
- Probe: 13" Length x 3/8" O.D. Inconel with pistol grip handle*
- Sample Line: 15' high temp flex hose with thermocouple wire*
- Weight: 28 lbs
|
|
Electrical: |
- AC: 110/220V 50/60Hz (User selectable)
- Batteries: 6-8 hour battery life, 6V lead-acid
- Pump: Flow rate of 3.5+ lpm
- Display: Backlit, adjustable contrast/zoom, (Displays all parameters simultaneously)
|
|
Operating Temperature: |
- Core temperature of the instrument is monitored continuously
- Internal temperature compensation software assures accurate sensor response over the range of 20°F to 104°F
|
|
|